Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 4 de 4
Filter
Add filters








Year range
1.
Bol. méd. Hosp. Infant. Méx ; 76(3): 138-145, may.-jun. 2019. graf
Article in English | LILACS | ID: biblio-1038899

ABSTRACT

Abstract Background A rare case of primary papillary thyroid cancer (PTC) and growth hormone (GH) deficiency in a pediatric patient is described. In addition, the patient developed fatty liver disease attributed to GH deficiency. Case report A 10-year-old male with a history of PTC with extension to the cervical nodes detected at 5 years of age was referred to the endocrinology consultation due to a low growth rate. On examination, GH deficiency was detected (height −3.51 standard deviations and low insulin-like growth factor-1 levels). This hormonal deficiency was not associated with thyroid cancer or treatment. Furthermore, elevated transaminases (~300 IU/ml), lipids, and fally liver disease by ultrasound were detected. These data suggested fatty liver disease, which was attributed to GH deficiency. Regardless of the risk of recurrence, somatotropin was administered due to liver dysfunction and very short stature of the patient. A considerable improvement in growth, transaminases, and lipid profile was observed. At present, at 14 years of age, resolution of hepatic steatosis and a considerable increase in his growth rate without recurrence of thyroid cancer 9 years after its diagnosis and 4 years after the initiation of GH treatment are confirmed. Conclusions GH therapy could be a good therapeutic option for pediatric cancer survivors to address impaired growth and fatty liver disease. However, additional medical evidence based on clinical trials is necessary to determine the benefits.


Resumen Introducción Se presenta el caso de un paciente pediátrico con una asociación de cáncer papilar de tiroides (CPT) y deficiencia de hormona de crecimiento (HC) que no ha sido descrita previamente. Además, presenta enfermedad hepática grasa atribuida a la deficiencia hormonal. Caso clínico Paciente de sexo masculino con antecedente de CPT con extensión a los ganglios cervicales diagnosticado a los 5 años de edad. Es referido a los 10 años por talla baja, sin datos de recurrencia del CPT. En el abordaje diagnóstico se detecta deficiencia de HC basándose en una estatura 3.51 desviaciones estándar por debajo de la media y niveles bajos de factor de crecimiento insulínico tipo 1. Adicionalmente, se detectó elevación de transaminasas (~300 IU/ml), dislipidemia y esteatosis hepática en el ultrasonido. Después de los estudios de extensión, la enfermedad hepática grasa se atribuyó a la deficiencia de HC. A pesar del riesgo de recurrencia del cáncer de tiroides, se decidió dar tratamiento con HC debido a la afectación hepática y de crecimiento. El paciente presentó una evolución satisfactoria y actualmente, a la edad de 14 años, la esteatosis hepática está resuelta, presenta una mejoría considerable en su estatura y no ha tenido recurrencia del cáncer de tiroides 9 años después del diagnóstico y 4 años después del inicio del tratamiento con HC. Conclusiones El tratamiento con HC puede ser una adecuada opción terapéutica para sobrevivientes de cáncer en la edad pediátrica con afectación en el crecimiento y esteatosis hepática. Sin embargo, se requieren estudios con mayor evidencia científica y seguimiento a largo plazo para apoyar esta afirmación.


Subject(s)
Child , Humans , Male , Human Growth Hormone/administration & dosage , Hormone Replacement Therapy/methods , Fatty Liver/drug therapy , Thyroid Cancer, Papillary/pathology , Treatment Outcome , Human Growth Hormone/deficiency , Fatty Liver/etiology , Fatty Liver/pathology , Cancer Survivors
4.
Bol. méd. Hosp. Infant. Méx ; 62(2): 96-103, mar.-abr. 2005. ilus, tab
Article in Spanish | LILACS | ID: lil-700748

ABSTRACT

Introducción. La angiografía digital (AD) transcateterismo es el estándar de oro en el diagnóstico de la coartación de aorta (CoAo) aunque la resonancia magnética (RM) ha mostrado utilidad en la evaluación del sistema cardiovascular. La medición de los segmentos del arco aórtico facilita la selección de los candidatos para angioplastia transcateterismo evitando una cirugía torácica. No hay reportes de estudios comparativos de las medidas de los diferentes segmentos aórticos, obtenidas por RM y AD. Material y métodos. Se estudiaron 49 pacientes con RM y AD que ingresaron con CoAo entre enero de 2002 y diciembre de 2003. Se determinó el tipo de CoAo. Se midieron los segmentos aórticos por RM y AD y se compararon por medio de correlación lineal (Pearson). En 43 pacientes se realizó angioplastia con globo. Resultados. La variabilidad en la medición de los diferentes segmentos entre ambos métodos fueron: aorta ascendente 1.99-2.10 mm (desviación estándar (DE) 2.7-2.8), arco aórtico 1.79-2 mm (DE 2.55-2.99), istmo 1.53-1.56 mm (DE 2-2.17), aorta descendente 1.75-1.78 mm (DE 2.54-2.55). Las medidas comparadas por correlación lineal muestran r entre 0.80 y 0.999, excepto en arco aórtico por RM que obtuvo r de 0.57. Conclusión. La evaluación con RM de niños con CoAo puede sustituir a la realizada mediante AD ya que una variación de 1.5 a 2.1 mm en las medidas obtenidas por ambos métodos no interfiere con la decisión terapéutica. Sólo debe realizarse la medición del arco aórtico en 2 proyecciones.


Introduction. Quantitative aortic arch analysis may improve the selection of candidates for angioplasty who are most likely to benefit from the procedure. Digital angiography (DA) has traditionally been the definitive preoperative diagnostic procedure for aortic coarctation (AoCo), but magnetic resonance (MR) imaging affords good spatial resolution and excellent contrast between blood vessels and soft tissues and offers great potential for delineating thoracic cardiovascular structures. Material and methods. Forty nine patients with AoCo were examined with MR and DA between June 2002 and December 2003. The site and type of AoCo were determined and the measurements of aortic arch segments were obtained. We realized balloon angioplasty in 43 patients. Results. We compared the measurements using Pearson's linear correlation. The variability of the measurements was: ascending aorta 1.99-2.1 mm (standard deviation [SD] 2.7-2.8), aortic arch 1.79-2 mm (SD 2.55-2.99), aortic isthmus 1.53-1.56 mm (SD 2-2.17), and descending aorta 1.75-1.78 mm (SD 2.54-2.55). The lineal correlation of Pearson for measurements were; r =0.80-0.999 but the aortic arch was r =0.57 by MR. Conclusion. We conclude that quantitative MR measurements of aorta may be used to diagnose of AoCo and avoid using DA. To obtain precise measurements of aortic arch in patients with AoCo, MR should include 2 projections.

SELECTION OF CITATIONS
SEARCH DETAIL